Joule Unvented DHW Cylinders - Stainless Steel
Size
Joule Unvented DHW Cylinders - Stainless Steel
200L Cyclone Ind HG SHORT C - 1150H x 600D
Spire Renewables - 7a
Spire Renewables, Unit 7A, Moy Road Industrial Estate
Taff's Well
Cardiff CF15 7QR
United Kingdom
Get it between -
UNVENTED DHW CYLINDER - JOULE - STAINLESS STEEL - 200L CYCLONE IND HG SHORT C - 1150H X 600D and UNVENTED DHW CYLINDER - JOULE - STAINLESS STEEL - 250L CYCLONE IND HG SHORT C - 1400H X 600D:
Heat Pump ready High-Gain DHW cylinder. Constructed with high-grade Duplex stainless steel, this Joule Cylinder is fitted with branded quality components ready for easy installation. The Cyclone unvented Cylinder comes in a sleek grey finish.
- Constructed from high-grade Duplex stainless steel.
- Unvented
- Fitted with branded quality components.
- Heat Pump, Gas or oil boiler ready.
UNVENTED DHW CYLINDER - JOULE - STAINLESS STEEL - 250/90L TANK ON TANK HI GAIN BUFFER C - 1950H X 600D:
250/90 ‘Tank on Tank’ (High-Gain DHW cylinder and buffer combination) for easy installation in space restricted plant areas. Constructed with high-grade Duplex stainless steel, this Joule Cylinder/buffer is fitted with branded quality components, pre-built ready for easy installation. The Cyclone unvented Cylinder comes in a sleek grey finish.
- Constructed from high-grade Duplex stainless steel.
- Unvented
- Fitted with branded quality components.
- Heat Pump, Gas or oil boiler ready.
- Integrated buffer tank for compact plantroom.
Data 200l:
Max mains water pressure (Bar) | 10 | Operating temp (C) | 60 |
Operating pressure (Bar) | 7 | Safety valve temp (C) | 90 |
Tested to standard | BS EN 12897:2016 | Warranty terms (Year) | 25Y |
No heat exchangers | 1 | Heat loss | 1.872 |
Coil 1 rating (kW) | 39 | Coil 1 surface area (m²) | 2.5 |
Coil 1 max prim pressure (Bar) | 3.5 | Coil 1 resistance (Bar) | .07 |
Data 250l:
Max mains water pressure (Bar) | 10 | Operating temp (C) | 60 |
Operating pressure (Bar) | 7 | Safety valve temp (C) | 90 |
Tested to standard | BS EN 12897:2016 | Warranty terms (Year) | 25Y |
No heat exchangers | 1 | Heat loss | 2.09 |
Coil 1 rating (kW) | 42 | Coil 1 surface area (m²) | 2.8 |
Coil 1 max prim pressure (Bar) | 3.5 | Coil 1 resistance (Bar) | .09 |
Data 300l:
Max mains water pressure (Bar) | 10 | Operating temp (C) | 60 |
Operating pressure (Bar) | 7 | Safety valve temp (C) | 90 |
Tested to standard | BS EN 12897:2016 | Warranty terms (Year) | 25Y |
No heat exchangers | 1 | Heat loss | 2.21 |
Coil 1 rating (kW) | 45 | Coil 1 surface area (m²) | 3 |
Coil 1 max prim pressure (Bar) | 3.5 | Coil 1 resistance (Bar) | .09 |